应用笔记
Roughness Evaluation of the Side Surface of Piston Rings
Piston ring
Application
Piston rings are attached to pistons to ensure that an engine’s combustion chamber remains airtight. The sides of piston rings need to maintain a certain level of roughness as they slide against the cylinder sleeve (the liner inside the cylinder). This roughness is integral to ensuring the smooth movement of the pistons in the cylinder while minimizing the abrasion caused by friction. Verifying the surface roughness of piston rings is essential during quality management inspections. Because piston rings are thin and ring-shaped, microscopic inspection of the sides involves securing the sample vertically in a customized fixture. When the piston ring is placed on the observation stage of a microscope fixed in this position, it can obstruct the movement of the objective lens.
Piston ring secured in a fixture
Olympus’ solution
The Olympus LEXT OLS5000 3D measuring laser microscope is used to measure surface roughness.
The OLS5000 microscope, when fitted with an optional extension frame, is capable of measuring samples up to 210 mm in height, enabling the observation of piston rings mounted in a fixture.
OLS5000 microscope features
- The microscope’s extension frame enables the observation/measurement of samples up to 210 mm in height.
- Measurement performance is enhanced to 4 times the speed of the previous LEXT model.
- Superior resolution (plane resolution: 0.12 µm) achieves high-precision measurement.
- Smart scan functionality for the acquisition of high-precision data helps eliminate data inconsistencies between operators.
Roughness evaluation of the side surface of a piston ring
Piston ring set on the stage of a LEXT OLS5000 microscope
Laser microscopy imagery of the side surface of a piston ring
(50X objective lens; 1x zoom)
应用所使用的产品
LEXT OLS5500
全新一代 精准测量 激光共聚焦显微镜
- 从纳米级至微米级的可追溯表面测量
- 一个获奖平台融合了激光扫描显微镜(LSM)、白光干涉仪(WLI)和焦点变化显微镜(FVM)技术
- 一款能够同时为 LSM 和 WLI 测量提供准确性和重复性* 保证的显微成像平台
- WLI 模式的测量通量比我们的传统 LSM 提高达 40 倍。
- 采用自主设计的光学系统,为表面测量提供卓越的测量精度
- 直观界面结合智能自动化,满足不同经验级别用户的操作需求
- 集成 PRECiV™ 软件的 AI 增强型高通量工作流程
* 根据 Evident 截至 2025 年 10 月的内部研究结果。设备必须按照制造商的规格进行校准并且不存在任何缺陷时,方可保证测量的准确性和可重复性。 校准必须由 Evident 的技术人员或 Evident 授权的专家执行。
LEXT OLS5100
具有出色精度和光学性能的LEXT™OLS5100激光扫描显微镜配备了让系统更加易于使用的智能工具。其能够快速高效完成亚微米级形貌和表面粗糙度的精确测量任务,既简化了工作流程又能让您获得可信赖的高质量数据。