Measuring the Roughness of Lithium-Ion Battery Electrodes Using a Laser Microscope

Positive electrode(Left) Negative electrode(Right)
Positive electrode(Left) Negative electrode(Right)

Application—Surface Roughness Checks of Electrode

Lithium-ion batteries charge and discharge because their lithium ions can move in both directions between positive and negative electrodes. Until recently, they had been mainly used in compact form in PCs, mobile phones, and digital cameras, but the demand is increasing for lithium-ion batteries with an electric capacity that is large enough for electric vehicles (EVs).
The basic process for manufacturing an electrode for lithium-ion batteries is as follows:

  1. Apply an electrode slurry material to a metal foil sheet called a collector.
  2. After the electrode slurry is dry, press the sheet.
  3. Using a slitter or cutter, cut the sheet into pieces of a specified size.

The electrode material on the sheet needs to have proper surface roughness to securely adhere to the separator. For this reason, surface roughness measurement using a roughness measuring instrument is necessary.
There are various types of surface roughness measuring instruments, but to accurately measure the surface roughness of electrodes, the options are limited. With contact-type roughness gages there is a risk of damaging the electrode surface, while interferometers are unreliable because the black electrodes absorb the light they use for measurement.

Olympus’ Solution Using the LEXT OLS5100 Microscope

The noncontact measurement of the LEXT OLS5100 3D laser scanning microscope is well-suited for measuring surface roughness of large electrodes for several reasons:

Images

Example of roughness measurement of a positive electrode
Example of roughness measurement of a positive electrode

Example of roughness measurement of a negative electrode
Example of roughness measurement of a negative electrode


https://main--eds-evident-website--evident-scientific.aem.live/es/microscopes/laser-confocal/ols5100/

LEXT OLS5100

El microscopio de escaneo láser LEXT™ OLS5100 combina precisión y rendimiento óptico a un nivel excepcional junto con herramientas inteligentes que facilitan su uso. Las tareas de medición precisa y submicrométrica con respecto a la forma y la rugosidad superficial son rápidas y eficientes, lo que simplificará su flujo de trabajo y proporcionará datos de alta calidad en los que puede confiar.