FV5000 Confocal Laser Scanning Microscope

Push the boundaries of microscopy further than ever before with the FLUOVIEW™ FV5000 confocal laser scanning microscope. Built on Evident’s renowned optical expertise and enhanced with advanced detection and scanning technologies, the FV5000 sets a new standard in precision imaging with extraordinary clarity, speed, and reliability.

Our groundbreaking SilVIR™ detectors deliver photon-level quantitation, while redesigned scanner control enables 2K resonant and 8K galvo scanning to capture dynamic events with sharper precision. Smart automation streamlines workflows, and built-in stability ensures reproducible results. Built from legacy and driven by innovation, the FV5000 turns complex imaging into confident discovery.

  • Product Status: This product is a replacement for the FV4000, FV3000, and earlier FV series systems.

https://adobeassets.evidentscientific.com/content/dam/mis/fv5000/videos/fv5000_launch_video.mp4

Simply Powerful Imaging: Faster, Smarter, Clearer

The FLUOVIEW FV5000 is a platform built for every dimension of discovery. From crisp, photon-level quantitation at the surface to deep, multiphoton imaging in thick, living samples, the FV5000 captures biology at every scale.

SilVIR™ detectors deliver exceptional sensitivity, a wide dynamic range, and photon-level precision, while 2K resonant and 8K galvo scanners freeze motion in real time for exceptional clarity. Smart automation simplifies setup and workflow and ensures consistent, reproducible results.

Combining advanced detection, intelligent design, and intuitive operation, the FV5000 makes powerful imaging more accessible than ever, helping researchers capture more detail, more reliably, in less time.

Download Brochure

View FV5000 Webinar

Precision Imaging You Can Trust

Born from more than 100 years of optical excellence, the FV5000 is setting a new standard in life science imaging for neuroscience, cell biology, drug discovery, cancer research, and developmental biology—delivering clear answers to challenging biological questions. The FV5000 is a next-generation platform designed to capture sharper, fully quantifiable data faster and easier than ever before:

  • Unmatched dynamic range of 1 Gcps with high-SNR SilVIR detectors, trusted by leading research institutions
  • High-density pixel scanners with 8K fast galvo and 2K high-speed resonant imaging
  • FLUOVIEW Smart™ software interface and AI-powered workflows
  • TruResolution™ automated correction collar for instant spherical aberration correction with over 20 of our standard objectives
  • Modular, future-ready system design: integrate up to 10 laser lines and compact multiphoton upgrades

Try the FV5000 yourself—it will be the last laser scanning microscope you demonstrate.

Request a Demo

Mouse brain slice expressing 7-color Tetbow cleared with SeeDB2.

Mouse brain slice expressing 7-color Tetbow cleared with SeeDB2 (in utero electroporation). Sample courtesy of: Drs. Satoshi Fujimoto and Takeshi Imai, Graduate School of Medical Sciences, Kyushu University.

Absolute Quantitation

MAP2 (green) and Hoechst (blue) in a cortical organoid at DIV 45 with cell line KOLF2.1J.

MAP2 (green) and Hoechst (blue) in a cortical organoid at DIV 45 with cell line KOLF2.1J. Sample courtesy of: Declan J. Brennan, Nygaard Lab at UBC.

Absolute Quantitation—Every Pixel, Every Run

The new benchmark in advanced microscopy, our SilVIR™ detectors deliver photon-level quantitation with exceptional sensitivity and ultra-high signal-to-noise across the industry’s widest dynamic range. Trust the industry’s first built-in laser power monitor to ensure consistent, reproducible illumination from samples captured today and in the future.

Finally, combine beautiful images with beautifully quantifiable results.

Jonathan Epp, PhD

“The dynamic range of the detectors has allowed us to image a number of different labels that we were not able to previously accomplish without making compromises over what gets over- or under-exposed.”

Jonathan Epp, PhD
Department of Cell Biology and Anatomy, University of Calgary

SilVIR™ Next-Generation Detector Technology

Built on Evident’s patented silicon photomultiplier design, SilVIR technology captures every photon with exceptional sensitivity and the industry’s widest dynamic range. Low-noise electronics and a built-in laser power monitor maintain illumination stability and ensure reproducible, quantitative results from faint signals to deep-tissue imaging.

SilVIR detector technology. Histograms show discrete photon counts with quantifiable intensity and minimum background.

Expect exceptional imaging from every level of signal. Clear high and ultra-low signals from the same sample with no compromise in quality. Histograms show discrete photon counts with quantifiable intensity and minimum background.

Comparison images showing image saturation from a GaAsP-PMT detector (in red) and the same image captured with the SilVIR detector (no saturation).

Top: Image saturation seen with a GaAsP-PMT detector (in red). Bottom: Same image captured with the SilVIR detector (no saturation).

Leave Saturated Images in the Past

With its expansive dynamic range, the SilVIR detector prevents signal clipping and minimizes time spent adjusting settings. Each capture delivers valid, unsaturated data ready for deconvolution, stitching, or spectral unmixing.

From single-photon events to intense fluorescence, SilVIR records the full signal spectrum in one acquisition. High dynamic range preserves faint details while preventing saturation of bright regions, reducing the need for reacquisition and ensuring consistent, quantitative image analysis.

Learn More About the SilVIR Detector

Read the White Paper

Speed and Resolution

Two Scanners, One Workflow: High-Density Sampling and High-Speed Imaging. No Compromises.

Whether you need high-speed series or pixel-dense maps, the FV5000 adapts. Our resonant scanner captures fast cellular dynamics at full clarity across a 20 mm FOV with little to no averaging, giving you high-quality, high-SNR raw images, in up to 438 FPS.

Switch to 8K × 8K galvo scanning to image large areas at high spatial resolution with ultra-fast pixel dwell times as short as 0.2 µs. Achieve up to 120 nm XY resolution across six spectral channels with high NA objectives and FV-OSR software—no additional hardware required.

The result: fewer compromises and faster time to data.

Stitched mouse brain slice cleared with SeeDB2.

Stitched mouse brain slice cleared with SeeDB2. EYFP is expressed in cortical layer 5 pyramidal neurons in Thy1-YFP-H transgenic mice, acquired with a LUPLAPO25XO objective lens and resonant scanner. Sample courtesy of: Drs. Satoshi Fujimoto and Takeshi Imai, Graduate School of Medical Sciences, Kyushu University.

Comparison images showing images captured with the FV5000’s galvo (left) and resonant (right) scanners, highlighting that you can acquire up to nine times faster than galvo with the same stunning clarity.

Acquire up to nine times faster than galvo with the same stunning clarity. Left: 43.5 minutes with 2K galvo Z-stack (galvo scan with no accumulation). Right: 4.6 minutes with 2K resonant Z-stack (resonant scan with 4x accumulation).

Mouse brain cleared with SeeDB2. EYFP is expressed in cortical layer 5 pyramidal neurons in Thy1-YFP-H.

Sample courtesy of: Drs. Satoshi Fujimoto and Takeshi Imai, Graduate School of Medical Sciences, Kyushu University.

Effortless Super-Resolution Imaging

Powerfully Accessible Subcellular Answers

Achieve super-resolution imaging on the FV5000 with no additional hardware. By pairing high NA objectives, such as our A Line™ HR series, with FV-OSR software, you can resolve subcellular structures down to 120 nm in XY with ease.

FV-OSR automatically adjusts the confocal aperture to capture and enhance high-frequency signal components, producing crisp, detailed images in real time. Combined with the sensitivity of the SilVIR detector, the FV5000 delivers simultaneous super resolution across up to six spectral channels.

Take your imaging—and your discoveries—further than ever before.

Cultured HeLa cells acquired in super-resolution mode on the FV5000 confocal laser scanning microscope.

Cultured HeLa cells expressing Lifeact-mScarlet-I and EB3- 3xmNeonGreen. Acquired with super-resolution mode on the FV5000. Sample courtesy of: Haruka Mii, Prof. Kazuhiro Aoki, Graduate School of Biostudies, Kyoto University. To learn more about the life of Henrietta Lacks and her contribution to modern medicine, visit henriettalacksfoundation.org.

Unmatched dynamic range combined with effortless Nyquist, big picture, and fine details. Galvo 8192 × 8192, zoom 0.9x, 0.8 a.u., LUPLAPO25XO objective lens, Ypet: 514 / 530-570, Z: 60-150 µm, Z step: 0.82 µm, MIP.

Unmatched dynamic range combined with effortless Nyquist, big picture, and fine details. Galvo 8192 × 8192, zoom 0.9x, 0.8 a.u., LUPLAPO25XO objective lens, Ypet: 514 / 530-570, Z: 60-150 µm, Z step: 0.82 µm, MIP.

Mouse brain slice cleared with SeeDB2. YPet is expressed in layer 2/3 pyramidal neurons (in utero electroporation).Sample courtesy of: Drs. Satoshi Fujimoto and Takeshi Imai, Graduate School of Medical Sciences, Kyushu University.

Capture Fast Responses

Thanks to the high SNR of the SilVIR detector, only minimal image averaging or accumulation is required to achieve high-quality results.

Live imaging of an acute olfactory bulb slice expressing GCaMP6f cleared with SeeDB-Live. Image acquired with a LUPLAPO25XS objective lens at 70 µm depth from the surface. Sample courtesy of: Drs. Shigenori Inagaki, Takeshi Imai, Graduate School of Medical Sciences, Kyushu University.

https://adobeassets.evidentscientific.com/content/dam/mis/fv5000/videos/product-page/70um-depth.mp4

Live imaging of an acute olfactory bulb slice expressing GCaMP6f cleared with SeeDB-Live. Image acquired with a LUPLAPO25XS objective lens at 120 µm depth from the surface. Sample courtesy of: Drs. Shigenori Inagaki, Takeshi Imai, Graduate School of Medical Sciences, Kyushu University.

https://adobeassets.evidentscientific.com/content/dam/mis/fv5000/videos/product-page/120um-depth.mp4

Live imaging of an acute olfactory bulb slice expressing GCaMP6f cleared with SeeDB-Live. Image acquired with a LUPLAPO25XS objective lens at 200 µm depth from the surface. Sample courtesy of: Drs. Shigenori Inagaki, Takeshi Imai, Graduate School of Medical Sciences, Kyushu University.

https://adobeassets.evidentscientific.com/content/dam/mis/fv5000/videos/product-page/200um-depth.mp4

Biology in Motion, from Cells to Embryos

See biology in motion, in detail. From FRAP to ablation, SilVIR quantitative detection and fast scanning allow you to capture weak signals with minimal averaging, delivering high SNR at real-time frame rates.

In living samples, precise stimulation enables repeatable, targeted perturbations, so you can track repair, migration, and signaling over time. A wide linear dynamic range helps prevent saturation, keeping time-lapse data analysis-ready.

Time-lapse sequence in a living zebrafish embryo.

Time-lapse sequence in a living zebrafish embryo showing the repair response after localized multiphoton ablation of microtubules (green). Sample courtesy of: Soraya Villaseca, PhD , Department of Physiology, Development and Neuroscience, University of Cambridge.

Soraya Villaseca, PhD.

“The quality of imaging, I’ve never seen something similar before.”

Soraya Villaseca, PhD
Department of Physiology, Development and Neuroscience, University of Cambridge

Unmatched Simplicity

End-to-End Simplicity with FLUOVIEW Smart™ Software

Inspired by real researchers tackling the challenges of science, the FV5000 is transforming confocal imaging, making it smarter and faster.

  • Smart Sample Search quickly locates your sample in XY and Z
  • Smart Auto Laser Power Adjustment uses AI to optimize signal-to-noise across power setting
  • Intuitive interface captures complex multidimensional images in just a few clicks
  • Intelligent Shading Correction automatically creates seamless, high-quality stitched images

Note: FLUOVIEW Smart is available with FV5000 inverted configurations. FLUOVIEW Smart is not compatible with gantry, upright, or MPE configurations.


Read more about how Evident is revolutionizing confocal microscopy with FLUOVIEW Smart’s intuitive AI-enhanced workflows.

FLUOVIEW Smart software interface.

Smart Simplicity in Action

Automated Correction Collar Adjustment

The FV5000’s integrated TruResolution™ technology simplifies one of microscopy’s most tedious alignment tasks: objective collar adjustment. In a single click, the system automatically locates the optimal collar position for your sample, eliminating manual trial and error.

For thick specimens, TruResolution dynamically fine-tunes the collar during XYZ scans to maintain consistent image sharpness throughout the entire volume. Compatible with many standard objectives, it delivers uniform clarity across diverse samples and imaging conditions.

TruResolution automated correction collar.

TruResolution technology automates correction collar adjustment. It fine-tunes objective settings to minimize spherical aberrations from cover glass and sample heterogeneity over depth, with broad objective compatibility.

Comparison images without the TruResolution auto correction collar (left) and with the collar (right).

Left: Without auto correction collar. Right: With auto correction collar. Automated correction collar adjustment delivers sharper, more detailed images

Intelligent Shading Correction

For edge-to-edge clarity and precision, automatically create seamless, high-quality stitched images with Intelligent Shading Correction.

Comparison stitched images without Intelligent Shading Correction (left) and with Intelligent Shading Correction (right).

Left: Without Intelligent Shading Correction. Right: With Intelligent Shading Correction. Intelligent Shading Correction automatically compensates for uneven illumination across the field of view to generate stitched images without manual adjustment, improving efficiency and consistency in large-area imaging.

Human iPSC-derived kidney organoids shown as a raw image (top) and TruAI image (bottom).

Above line: Raw image. Below line: TruAI image.

Human iPSC-derived kidney organoids with membrane-GFP. GFP signal immuno-amplified using anti-GFP primary and Alexa Fluor 488 secondary; laminin-111/211 labeled with Alexa Fluor 568; nuclei stained with DAPI. Captured with single-wavelength fiber-pigtailed IR lasers at 920 nm and 1064 nm for simultaneous 3CH multiphoton imaging at 2K resonant imaging. Sample courtesy of: Dr. Robert Turnbull and Prof. Katja Röper, Department of Physiology, Development and Neuroscience, University of Cambridge.

Software Tools as Dynamic as Your Science

Minimize Noise, Maximize Data

The FV5000’s software ecosystem includes advanced AI tools that enhance image quality, accelerate analysis, and streamline complex workflows, all without sacrificing scientific rigor.

TruAI noise reduction further improves the FV5000’s already high signal-to-noise ratio by using neural networks trained on SilVIR detector noise patterns. Whether applied in real time or post-processing, TruAI restores clarity in resonant images and preserves temporal resolution while reducing photodamage.

To speed downstream analysis, pretrained AI models can automatically segment image data, minimizing manual workload and ensuring faster, more consistent results across experiments.

Image Segmentation Powered by Deep Learning

Go Beyond Conventional Thresholds

Traditional intensity-based thresholding can be slow, inconsistent, and highly sensitive to sample conditions.

TruAI image segmentation uses deep learning to recognize subtle patterns and faint signals that conventional methods miss, enabling accurate, reproducible segmentation of weakly labeled structures and complex tissues.

Clearly distinguish cells—and quickly find answers.

Spheroid imaging and analysis with TruAI. Left: Without TruAI. Right: With TruAI.

Spheroid imaging and analysis with TruAI. Left: Without TruAI. Right: With TruAI. TruAI segments and classifies cells (images on the right), even at high-penetration depths when the nuclei DAPI signal becomes weaker due to scattering.

Reliability and Flexibility

Engineered for Long-Term Precision, Built to Last

The FV5000 is engineered for long-term precision and adaptability, delivering the reliability and flexibility your science demands. Configure your system for today’s needs and expand effortlessly as your research evolves.

Add detectors, cameras, or lasers as workflows advance, or upgrade to multiphoton imaging with the MPE module, enabling single- and multiphoton acquisition as well as second and third harmonic generation. Smart hardware and software continuously monitor and optimize imaging performance, ensuring consistent, reproducible results. And with Evident’s global service and support network, every system is built to deliver lasting confidence and uptime.

Built for Reproducibility

The FV5000 maintains measurement precision through active system monitoring. The Laser Power Monitor (LPM) ensures consistent laser output across sessions, allowing different users to acquire images under identical conditions, even days or weeks apart. This stability supports the reproducibility required for quantitative and longitudinal studies.

To further safeguard performance, the Microscope Performance Monitor (MPM) automatically evaluates system sensitivity and imaging consistency. It detects deviations early, helping researchers maintain confidence in their results and ensuring every dataset reflects true experimental conditions.

Read the White Paper

The FV5000 microscope’s Laser Power Monitor.

High-resolution five-channel confocal image of an embryo

High-resolution five-channel confocal image of an embryo captured using DAPI and Alexa Fluor™ 488, 568, 647, and 750—revealing detailed structures across multiple fluorescence spectra.

More Colors and More Information

Capture more colors and extract more information from every image using the FV5000’s enhanced multiplexing capabilities. Updated TruSpectral™ technology, in combination with the high-sensitivity SilVIR detector, enables simultaneous acquisition of up to six channels, configurable with a selection of broadband and red-shifted detectors to accommodate a broader range of fluorochromes.

This configuration supports flexible experimental design, helping to reduce autofluorescence and photodamage during live-cell imaging. Modular laser combiners allow the integration of up to 10 laser lines, spanning wavelengths from 405 to 785 nm, to operate in parallel.

Configurations

Designed for Every Application

The FV5000 platform supports a full range of configuration, from IX85 inverted systems for high-speed live-cell imaging and upright frames for general imaging or electrophysiology, to gantry setups for large or irregular specimens. For deeper imaging, the MPE (multiphoton excitation) configuration enables small-animal and thick-tissue studies, including large-frame and 3D organoid-optimized designs.

Confocal and multiphoton modes can also be combined in a single system, giving researchers unmatched versatility within one platform. Up to six SilVIR detector channels can be configured for confocal imaging and an additional six for multiphoton detection, enabling a total of 12 configurable channels with photon-level sensitivity across modalities.

CONFOCAL

FV5000 confocal upright microscope system. Upright System

For glass slide sample imaging.

FV5000 confocal upright microscope system for eletrophysiology Upright System

For electrophysiology.

FV5000 gantry microscope system. Gantry System

For in vivo observation that requires maximum space.

FV5000 inverted microscope system. Inverted System

For observing tissue cultures, 3D cultures, and cell cultures (spheroids).

FV5000 confocal upright microscope system.

FV5000 confocal upright microscope system for eletrophysiology

FV5000 gantry microscope system.

FV5000 inverted microscope system.

Upright System

Upright System

Gantry System

Inverted System

For glass slide sample imaging.

For electrophysiology.

For in vivo observation that requires maximum space.

For observing tissue cultures, 3D cultures, and cell cultures (spheroids).

MULTIPHOTON

FV5000MPE upright microscope system.
FV5000MPE gantry microscope system.
FV5000MPE inverted microscope system.

Upright System

A large focus stroke accommodates a range of specimens, from tissue slices to live mice and other small animals.

Gantry System

The frame maintains a large working space below the objective, making it easier to position experiment equipment.

Inverted System

The frame supports observation of 3D cultures and multicellular clusters that are difficult to image using an upright frame.

Learn more about the FV5000MPE for mulitphoton applications.

World-Class Imaging Objectives

In addition to our award-winning X Line™ objectives, Evident offers an expansive range of A Line™ objectives that can meet any research need, pushing your confocal system even further.

Use our Objective Finder to locate the ideal objective for your application.

Evident’s silicone gel pad objective lens

“The gel objective is my favorite thing ever. Image quality and acquisition speed, and also sensitivity, were all very impressive.”

Emma Steijvers, MSc, MPhil
AROS Lab, Department of Physiology, Development and Neuroscience, University of Cambridge

New Oil Immersion Objective

Our new long WD oil immersion objective lens allows you to see details deep in cleared samples.

  • 25X / NA 1.0
  • Working distance: 1 mm
  • Immersion: oil
  • High refractive index sample coverage: 1.45–1.56 (Rapiclear, BABB, etc.)
  • APO chromatic aberration corrected
oil immersion objective.

Whole mouse embryo cleared with Ethyl cinnamate, labeled with Alexa Fluor 405, 488, and 568.

Captured in confocal mode (170 tiles in XY, 700 microns depth) with a 25X oil immersion lens (1 mm WD). Sample courtesy of: Dr. Emma Siragher, Hanna Group, Department of Physiology, Development and Neuroscience, University of Cambridge.

Scientists performing high-end life science research.

Driving the Future of High-End Imaging Research

The FV5000 combines precision engineering with intelligent automation to deliver reliable, reproducible results for every user—from core facilities to individual researchers.

  • Core Facilities: Long-term stability with SilVIR detectors, automated calibration, and a modular, future-ready design that minimizes downtime and simplifies management.
  • Research Leaders: Quantitative, publication-quality data through photon-level detection and automated workflows that accelerate discovery.
  • Individual Users: Intuitive operation, rapid setup, and integrated performance monitoring ensure confident imaging from day one.

Service

Support and Service You Can Count On

When it comes to protecting your investment and the integrity of your research, your needs come first. We stand behind our products with a commitment to prompt service and technical support to help you achieve your goals.

Available in three convenient tiers—Maintenance, Protection, and Performance Plus—our FV5000 Service Plans* include priority support to help minimize downtime, regular scheduled maintenance to keep your equipment in peak condition, predictable repair costs to eliminate unplanned expenses, and direct, efficient solutions when you need them most.

*Regional variations in service offerings may apply.

Evident service and support for microscopy and imaging solutions
Maintenance
Protection
Performance Plus
Priority remote support
Preventative maintenance

Repair coverage

(parts, labor, travel)

10% discount
Fast on-site response
-
-

Specifications

SPECIFICATIONS FV5000 FV5000-RS
Scanner Galvanometer Scanner 64 × 64 – 8192 × 8192 pixels, 0.2 μs/pixel – 1000 μs/pixel
Resonant Scanner 512 × 512 pixels, 1024 × 1024 pixels, 2048 × 2048 pixels
Field Number 20 (for both scanner types)
Spectral Confocal Detector Detector SilVIR detector (cooled SiPM, broadband type/red-shifted type)
Maximum Channels Six channels
Spectral Method VPH, detectable wavelength range: 400 nm-900 nm
Laser VIS Laser 405 nm, 445 nm, 488 nm, 514 nm, 561 nm, 594 nm, 640 nm
NIR Laser 685 nm, 730 nm, 785 nm
Laser Power Monitor Built in
Image High dynamic range photon counting (1G cps, 16-bit)

Resources

Application Notes

How To

White Papers

Insights

Videos

Product Resources