Application Notes

Olympus Industrial Resources

Contact us

Using the Olympus OLS5000 Laser Confocal Microscope to Measure Surface Roughness on the Metal Part of Dental Implants

Background

The surface roughness of the root portion of dental implants is important because roughness increases the overall surface area which, in turn, increases the implant’s stability. The metal portions of dental implants often undergo multiple processing stages to increase roughness including blasting, acid etching, anodic oxidation, and polishing. The optimum surface roughness for dental implants is between 1–10 μm. In Japan, dental implant manufacturers are required to verify the measurements of surface roughness using a laser confocal microscope. Failure to have appropriate roughness can lead to poor adhesion of an implant to a patient’s oral cavity.

The Olympus solutions

The Olympus LEXT laser confocal microscope offers exceptional accuracy and precision in measuring the roughness of dental implant surfaces. The LEXT’s high resolution and ability to measure steep angles mean that shapes of varying geometry are accurately and precisely measured (Figure 1). The microscope has long working distance objectives so that larger objects, such as dental implants, can be inspected.

Features of the product

The Olympus LEXT gives you the ability to make 3D observations with ultra-high-resolution measurements and a high pixel density. The varying objectives give you the flexibility of having a working distance capable of accommodating larger objects, such as dental implants. The LEXT features high inclination sensitivity for making accurate measurements of complex and steep-sided irregularities.

Image

Figure 1: Dental implant surface measurements using the LEXT

Products Used for This Application

LEXT OLS5500

Hybrid 3D Optical Profilometer

  • Traceable surface measurements from the nanometer to micrometer scale
  • Laser scanning microscopy (LSM), white light interferometry (WLI), and focus variation microscopy (FVM) in one award-winning platform
  • First 3D optical profilometer to offer guaranteed accuracy and repeatability* for both LSM and WLI measurements
  • WLI mode delivers up to 40x faster measurement throughput than conventional LSM
  • Exceptional precision across surfaces with in-house engineered optics
  • Intuitive interface and smart automation streamline operation for users of all levels
  • AI-enhanced and high-throughput workflows with PRECiV™ software integration

*Based on Evident’s internal research as of October 2025. The guaranteed accuracy and repeatability apply only if the device has been calibrated according to the manufacturer’s specifications and is in defect free condition. Calibration must be performed by an Evident technician or an Evident-authorized specialist.

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/laser-confocal/ols5100/

LEXT OLS5100 NEW

The LEXT™ OLS5100 laser scanning microscope combines exceptional accuracy and optical performance with smart tools that make the system easy to use. The tasks of precisely measuring shape and surface roughness at the submicron level are fast and efficient, simplifying your workflow and delivering high-quality data you can trust.