Application Notes

Contact Us

Measuring the Surface Roughness of Lithium-Ion Battery Electrode Collectors

aluminum copper
Collectors (left: aluminum, right: copper)

Application - Inspecting the Electrodes of Lithium-Ion Batteries

Materials generally used for lithium-ion battery electrodes are aluminum (positive electrode) and copper (negative electrode). During charge and discharge, electron transfer occurs between the collector and active material. At this contact point, when the resistance of the active materials becomes significant between the collectors and the interface, efficient electron transfer does not occur, and electric capacity decreases. If too much roughness forms on the collector’s metal foil, it increases the resistance of the active materials between the collectors and the interface and reduces overall electric capacity.

To help ensure that the batteries work properly, manufacturers measure the collectors’ surface roughness to make sure that the roughness falls within a certain range. The data are more reliable when the roughness measurement is performed for a plane, and the measurement range is as large as possible. Conventional contact-type roughness measuring instruments, however, can only perform linear roughness measurement and can damage the metal foil.

A Solution for Noncontact, Planar Roughness Measurement

Measurement using the Olympus LEXT 3D laser scanning microscope

OLS5000 Advantages: No Surface Contact, Dedicated Objective Lenses, Horizontal Data Stitching

  1. Unlike contact-type roughness gages, noncontact measurements ensure that delicate foil is not damaged during the measurement process. This, in turn, helps prevent data errors caused by damage to the sample.
  2. The LEXT OLS5000 uses dedicated objective lenses, so you can acquire data that is accurate both in the center of the field of view and the surrounding area.
  3. Data can be stitched horizontally, enabling data acquisition over a large area.
    Since the data from the stitched area is very accurate, the collector’s roughness data can be acquired with higher precision than with conventional measurement methods.
  4. A lineup of stages having a driving range of 300 mm × 300 mm enables you to measure even a large test object, like a collector used in automotive batteries, without the need to process them for a microscope.

Image

Roughness measurement of the copper foil of a negative electrode collector


Roughness measurement of the copper foil of a negative electrode collector

When measuring roughness using the Olympus LEXT OLS5000 microscope, the following types of information can be displayed: roughness data, laser microscope 3D pseudocolor images and height information, and optical microscope real-color images. This enables inspectors to confirm the roughness as a number. At the same time, inspectors can understand the state of the collector surface from the numerical data. By observing these images, inspectors can recognize the actual surface texture.

LEXT OLS5500

Hybrid 3D Optical Profilometer

  • Traceable surface measurements from the nanometer to micrometer scale
  • Laser scanning microscopy (LSM), white light interferometry (WLI), and focus variation microscopy (FVM) in one award-winning platform
  • First 3D optical profilometer to offer guaranteed accuracy and repeatability* for both LSM and WLI measurements
  • WLI mode delivers up to 40x faster measurement throughput than conventional LSM
  • Exceptional precision across surfaces with in-house engineered optics
  • Intuitive interface and smart automation streamline operation for users of all levels
  • AI-enhanced and high-throughput workflows with PRECiV™ software integration

*Based on Evident’s internal research as of October 2025. The guaranteed accuracy and repeatability apply only if the device has been calibrated according to the manufacturer’s specifications and is in defect free condition. Calibration must be performed by an Evident technician or an Evident-authorized specialist.

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/laser-confocal/ols5100/

LEXT OLS5100

The LEXT™ OLS5100 laser scanning microscope combines exceptional accuracy and optical performance with smart tools that make the system easy to use. The tasks of precisely measuring shape and surface roughness at the submicron level are fast and efficient, simplifying your workflow and delivering high-quality data you can trust.