Olympus Industrial Resources

Application Notes

Contact Us

Inspection of the processed shape of expanded metal

Non-contact 3D surface profile measurement using a laser microscope

Expanded metal
Expanded metal

1. Application

Expanded metal has a diamond-shaped ‘mesh’ structure created by slitting and stretching a metal plate in a press. This structure enables light, heat, sound, and air to pass through the expanded metal, and the structure’s mesh pattern has no joints, giving the metal superior mechanical strength (particularly in shear deformation stress). The thickness of the material plate and the size of the diamond-shaped pattern differ widely depending on the application. Expanded metal is used in internal and external building materials such as fences, automotive parts, external communication equipment, kitchen instruments, and farm equipment. When used as an arts and crafts supply, expanded metal typically has a mesh size of about 1 mm, and the plate is very thin (several hundred μm thick) and light. However, if the cut end is sharp or has burrs created during the process of slitting and stretching, users may be injured when they touch the expanded metal with bare hands. Therefore, it is important to observe the metal’s surface conditions, but visual observation is difficult due to the fineness of the cut end.

2. The Olympus solution

Olympus' LEXT 3D scanning laser microscope can be used as an optical microscope that enables users to easily switch from low to high magnification. Users also have the ability to acquire a high-resolution 3D surface profile from a specific area using the microscope’s laser. The LEXT microscope’s confocal optical system can create an all-in-focus image for reliable image data, and the dedicated optical system obtains maximum performance from the 405 nm laser, making it easy to determine if the cut end of the expanded metal has fine burrs. The microscope’s advanced features also make it simple to measure the height of any burrs that are located or analyze the roughness of a microscopic joint area. Small areas that could not be seen clearly with an optical microscope, such as edges, can be clearly observed with the LEXT microscope. The microscope’s stitching function makes it possible to view specimens with a wider field of view.

Images

Minute expanded metal Cu ob5X
Minute expanded metal Cu ob20X

LEXT OLS5500

Hybrid 3D Optical Profilometer

  • Traceable surface measurements from the nanometer to micrometer scale
  • Laser scanning microscopy (LSM), white light interferometry (WLI), and focus variation microscopy (FVM) in one award-winning platform
  • First 3D optical profilometer to offer guaranteed accuracy and repeatability* for both LSM and WLI measurements
  • WLI mode delivers up to 40x faster measurement throughput than conventional LSM
  • Exceptional precision across surfaces with in-house engineered optics
  • Intuitive interface and smart automation streamline operation for users of all levels
  • AI-enhanced and high-throughput workflows with PRECiV™ software integration

*Based on Evident’s internal research as of October 2025. The guaranteed accuracy and repeatability apply only if the device has been calibrated according to the manufacturer’s specifications and is in defect free condition. Calibration must be performed by an Evident technician or an Evident-authorized specialist.

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/laser-confocal/ols5100/

LEXT OLS5100

The LEXT™ OLS5100 laser scanning microscope combines exceptional accuracy and optical performance with smart tools that make the system easy to use. The tasks of precisely measuring shape and surface roughness at the submicron level are fast and efficient, simplifying your workflow and delivering high-quality data you can trust.